BWY2-804 / BWY2-806 Type II Transformer Oil Temperature Controller with Pt100 and 4-20mA Output

BWY2-804 / BWY2-806 Type II Transformer Oil Temperature Controller with Pt100 and 4-20mA Output

Product Overview

The BWY2-804 / BWY2-806 Type II Transformer Oil Temperature Controller is designed for monitoring, indicating and controlling oil temperature of oil-immersed transformers. It is a Type II transformer oil temperature instrument for on-site indication, alarm control, cooling system control and remote temperature monitoring.

This series adopts pointer-type temperature indication and can directly display transformer oil temperature on site. The instrument can be configured with 4 or 6 adjustable control switches for transformer cooling system control, temperature alarm and protection control.

According to different configurations, the product can provide Pt100 resistance signal output. It can also be connected with the TC-152 temperature transmitter to provide 4-20mA standard current signal output for secondary instruments, remote monitoring systems, PLC systems or automation control systems.


Key Features

  1. Type II instrument for oil-immersed transformer oil temperature monitoring and control.
  2. Local pointer-type temperature indication for on-site inspection.
  3. Available with 4 or 6 adjustable switch groups.
  4. Switch settings can be adjusted freely within the full measuring range.
  5. Supports Pt100 resistance signal output for remote temperature acquisition.
  6. Can be connected with TC-152 temperature transmitter for 4-20mA output.
  7. Suitable for temperature alarm, cooling system control and protection control.
  8. High-frequency welding process helps ensure sealing performance.
  9. Mechanical fatigue-resistant structure for stable long-term operation.
  10. Multiple output signal options are available with stable signal output.
  11. Temperature transmitter output adopts photoelectric isolation with 2000V isolation voltage.
  12. Lightning protection circuit design for power applications.
  13. Integrated mechanical and electrical design for convenient installation and maintenance.
  14. Multi-coil spring tube technology and bimetal ambient temperature compensation.
  15. Low error between the instrument body and remote monitoring system.
  16. Maintenance can be performed without power shutdown.
  17. IP55 protection grade for industrial operating environments.
  18. Standard 6m capillary tube, with customized length available upon request.

Technical Specifications

Specification
Product SeriesBWY2-804 / BWY2-806 Series
Product NameType II Transformer Oil Temperature Controller
Product TypePointer Type Transformer Oil Temperature Controller
Applicable EquipmentOil-immersed transformer, power transformer, substation and power distribution system
Output SignalPt100 resistance signal
Optional Output4-20mA current signal with TC-152 temperature transmitter
Operating Temperature-40C to +55C
Relative Humidity<=95%
Measuring RangeStandard -20-140C, optional 0-160C
AccuracyClass 1.5
Maximum Permissible Error+/-2.4C
Switch Groups4 or 6 adjustable switch groups
Switch SettingFreely adjustable within the full measuring range
Switch Action Error+/-2C
Switch Differential3-6C
Switch RatingAC220V / 5A, subject to nameplate or order configuration
Temperature Bulb SizePhi14 x 150mm
Mounting ThreadM27 x 2
Capillary Tube LengthStandard 6m, other lengths available upon request
Protection GradeIP55

Function Description

Oil Temperature Indication

The controller provides pointer-type indication of transformer oil temperature, helping operators check transformer operating status on site.

Remote Signal Output

The product supports Pt100 resistance signal output and can be connected with the TC-152 temperature transmitter to provide 4-20mA standard current signal for remote monitoring systems, secondary instruments, PLC systems or automation control systems.

Cooling System Control

When the oil temperature reaches the preset value, the controller can output a control signal to start or stop the transformer cooling system.

Temperature Alarm

When the transformer oil temperature exceeds the preset alarm value, the controller can output an alarm signal.

Protection Control

When the oil temperature exceeds the safety limit, the controller can provide a protection control signal to support transformer safe operation.

Multi-stage Control

With 4 or 6 adjustable switch groups, the product can meet multi-stage alarm, cooling control and protection requirements.


Model Code Description

Description
BWYTransformer oil temperature controller
2Type II instrument
8044 adjustable switch groups
8066 adjustable switch groups
APt100 signal output
J4-20mA signal output
AJPt100 signal and 4-20mA signal output
AADual Pt100 signal output
JJDual 4-20mA signal output
THHumid tropical protection
TADry tropical protection
TDry and humid tropical protection

Common Configurations

Description
BWY2-804Type II instrument with 4 adjustable switch groups
BWY2-806Type II instrument with 6 adjustable switch groups
BWY2-804AType II instrument with 4 adjustable switch groups and Pt100 output
BWY2-804JType II instrument with 4 adjustable switch groups and 4-20mA output
BWY2-804AJType II instrument with 4 adjustable switch groups, Pt100 and 4-20mA output
BWY2-804AAType II instrument with 4 adjustable switch groups and dual Pt100 output
BWY2-804JJType II instrument with 4 adjustable switch groups and dual 4-20mA output
BWY2-806JType II instrument with 6 adjustable switch groups and 4-20mA output

Applications

The BWY2-804 / BWY2-806 Type II Transformer Oil Temperature Controller is widely used in:

  1. Oil-immersed transformers
  2. Power transformers
  3. Transformer substations
  4. Power distribution systems
  5. Industrial power equipment
  6. Electrical control cabinets
  7. Transformer cooling control systems
  8. Transformer oil temperature monitoring systems
  9. Transformer temperature alarm systems
  10. Power equipment remote monitoring systems
  11. Unattended transformer monitoring systems

Installation and Customization

The standard capillary tube length is 6 meters. Other lengths can be customized according to project requirements. The temperature bulb size is Phi14 x 150mm, and the mounting thread is M27 x 2.

Customized output signal, switch quantity, measuring range, capillary tube length, protection type and power supply can be confirmed according to the actual application.


Ordering Information

To help us recommend the correct model, please provide the following information when sending an inquiry:

  1. Required series: BWY2-804 / BWY2-806
  2. Output signal: Pt100 / 4-20mA / Pt100 and 4-20mA
  3. Whether TC-152 temperature transmitter is required
  4. Switch quantity: 4 groups / 6 groups
  5. Measuring range: -20-140C / 0-160C
  6. Capillary tube length: 6m / customized length
  7. Mounting thread: M27 x 2
  8. Protection type: TH / TA / T
  9. Application: oil-immersed transformer / power transformer / distribution system
  10. Order quantity
  11. Destination country or region

Need Product Consultation?

Fill out the form below, our technical experts will contact you as soon as possible

Quick Response Professional Answers Free Quote